feat(itho-wpu): get datalog structure from the database

Instead of hardcoding the datalog structure for listversion 11 (my WPU
version), get the datalog structure from the database and match that
against the result from the getdatatype call.

This way all WPU versions that are in the database are automatically
supported.
This commit is contained in:
Pim van den Berg 2021-03-07 14:58:20 +01:00
parent 00f098f4e1
commit 96f91cb9d3

View File

@ -10,6 +10,7 @@ import time
import os import os
import datetime import datetime
import json import json
import db
from collections import namedtuple from collections import namedtuple
consolelogformatter = logging.Formatter("%(asctime)-15s %(levelname)s: %(message)s") consolelogformatter = logging.Formatter("%(asctime)-15s %(levelname)s: %(message)s")
@ -175,6 +176,7 @@ class IthoWPU():
self.cache = IthoWPUCache() self.cache = IthoWPUCache()
self.nodeid = self.get('getnodeid') self.nodeid = self.get('getnodeid')
self.datatype = self.get('getdatatype') self.datatype = self.get('getdatatype')
self.heatpump_db = db.sqlite('heatpump.sqlite')
def get(self, action): def get(self, action):
if not self.no_cache: if not self.no_cache:
@ -205,6 +207,45 @@ class IthoWPU():
return response return response
def get_listversion_from_nodeid(self):
if self.nodeid is None:
return
return int(self.nodeid[10], 0)
def get_datalog_structure(self):
listversion = self.get_listversion_from_nodeid()
datalabel_version = self.heatpump_db.execute(
f"SELECT datalabel FROM versiebeheer WHERE version = {listversion}")[0]['datalabel']
if datalabel_version is None or not type(datalabel_version) == int:
logger.error(f"Datalabel not found in database for version {listversion}")
return None
datalabel = self.heatpump_db.execute(
f"SELECT name, title, tooltip, unit FROM datalabel_v{datalabel_version} order by id")
if len(self.datatype[5:-1]) != len(datalabel):
logger.warning(f"Number of datatype items ({len(self.datatype[5:-1])}) is not equal to the number of datalabels ({len(datalabel)}) in the database.")
Field = namedtuple('Field', 'index type label description')
datalog = []
index = 0
for dl, dt in zip(datalabel, self.datatype[5:-1]):
description = dl['title'].title()
if dl['unit'] is not None:
description = f"{description} ({dl['unit']})"
datalog.append(Field(index, int(dt, 0), dl['name'].lower(), description))
if dt in ['0x0', '0xc']:
index = index + 1
elif dt in ['0x10', '0x12', '0x92']:
index = index + 2
elif dt in ['0x20']:
index = index + 4
else:
logger.error(f"Unknown data type for label {dl['name']}: {dt}")
return datalog
return datalog
class IthoWPUCache: class IthoWPUCache:
def __init__(self): def __init__(self):
@ -259,7 +300,7 @@ def is_messageclass_valid(action, response):
return True return True
def process_response(action, response, args): def process_response(action, response, args, wpu):
if int(response[3], 0) != 0x01: if int(response[3], 0) != 0x01:
logger.error(f"Response MessageType != 0x01 (response), but {response[3]}") logger.error(f"Response MessageType != 0x01 (response), but {response[3]}")
return return
@ -267,7 +308,7 @@ def process_response(action, response, args):
return return
if action == "getdatalog": if action == "getdatalog":
measurements = process_datalog(response) measurements = process_datalog(response, wpu)
if args.export_to_influxdb: if args.export_to_influxdb:
export_to_influxdb(action, measurements) export_to_influxdb(action, measurements)
elif action == "getnodeid": elif action == "getnodeid":
@ -302,42 +343,8 @@ def process_serial(response):
logger.info(f"Serial: {serial}") logger.info(f"Serial: {serial}")
def process_datalog(response): def process_datalog(response, wpu):
# 0 = Byte datalog = wpu.get_datalog_structure()
# 1 = UnsignedInt
# 2 = SignedIntDec2
Field = namedtuple('Field', 'index type label description')
datalog = [
Field(0, 0x92, "t_out", "Buitentemperatuur"),
Field(2, 0x92, "t_boiltop", "Boiler laag"),
Field(4, 0x92, "t_boildwn", "Boiler hoog"),
Field(6, 0x92, "t_evap", "Verdamper temperatuur"),
Field(8, 0x92, "t_suct", "Zuiggas temperatuur"),
Field(10, 0x92, "t_disc", "Persgas temperatuur"),
Field(12, 0x92, "t_cond", "Vloeistof temperatuur"),
Field(14, 0x92, "t_source_r", "Naar bron"),
Field(16, 0x92, "t_source_s", "Van bron"),
Field(18, 0x92, "t_ch_supp", "CV aanvoer"),
Field(20, 0x92, "t_ch_ret", "CV retour"),
Field(22, 0x92, "p_sens", "Druksensor (Bar)"),
Field(24, 0x92, "i_tr1", "Stroom trafo 1 (A)"),
Field(26, 0x92, "i_tr2", "Stroom trafo 2 (A)"),
Field(34, 0x10, "in_flow", "Flow sensor bron (l/h)"),
Field(37, 0x0, "out_ch", "Snelheid cv pomp (%)"),
Field(38, 0x0, "out_src", "Snelheid bron pomp (%)"),
Field(39, 0x0, "out_dhw", "Snelheid boiler pomp (%)"),
Field(44, 0xc, "out_c1", "Compressor aan/uit"),
Field(45, 0xc, "out_ele", "Elektrisch element aan/uit"),
Field(46, 0xc, "out_trickle", "Trickle heating aan/uit"),
Field(47, 0xc, "out_fault", "Fout aanwezig (0=J, 1=N)"),
Field(48, 0xc, "out_fc", "Vrijkoelen actief (0=uit, 1=aan)"),
Field(51, 0x92, "ot_room", "Kamertemperatuur"),
Field(55, 0x0, "ot_mod", "Warmtevraag (%)"),
Field(56, 0x0, "state", "State (0=init,1=uit,2=CV,3=boiler,4=vrijkoel,5=ontluchten)"),
Field(57, 0x0, "sub_state", "Substatus (255=geen)"),
Field(67, 0x0, "fault_reported", "Fout gevonden (foutcode)"),
Field(92, 0x10, "tr_fc", "Vrijkoelen interval (sec)"),
]
message = response[5:] message = response[5:]
measurements = {} measurements = {}
for d in datalog: for d in datalog:
@ -356,6 +363,11 @@ def process_datalog(response):
if num >= 32768: if num >= 32768:
num -= 65536 num -= 65536
num = round(num / 100, 2) num = round(num / 100, 2)
elif d.type == 0x20:
m = message[d.index:d.index+4]
num = ((int(m[0], 0) << 24) + (int(m[1], 0) << 16) + (int(m[2], 0) << 8) + int(m[3], 0))
else:
logger.error(f"Unknown message type for datalog {d.name}: {d.type}")
logger.info(f"{d.description}: {num}") logger.info(f"{d.description}: {num}")
measurements[d.label] = num measurements[d.label] = num
return measurements return measurements
@ -370,4 +382,4 @@ if __name__ == "__main__":
wpu = IthoWPU(args.master_only, args.slave_only, args.slave_timeout, args.no_cache) wpu = IthoWPU(args.master_only, args.slave_only, args.slave_timeout, args.no_cache)
response = wpu.get(args.action) response = wpu.get(args.action)
if response is not None: if response is not None:
process_response(args.action, response, args) process_response(args.action, response, args, wpu)