#!/usr/bin/env python3 import argparse import logging import queue import sys import time import os import json import db from collections import namedtuple from itho_i2c import I2CMaster, I2CSlave logger = logging.getLogger("stdout") logger.setLevel(logging.INFO) stdout_log_handler = logging.StreamHandler(sys.stdout) stdout_log_handler.setFormatter(logging.Formatter("%(message)s")) logger.addHandler(stdout_log_handler) actions = { "getnodeid": [0x90, 0xE0], "getserial": [0x90, 0xE1], "getdatatype": [0xA4, 0x00], "getdatalog": [0xA4, 0x01], } def parse_args(): parser = argparse.ArgumentParser(description="Itho WPU i2c master") parser.add_argument( "--action", nargs="?", required=True, choices=actions.keys(), help="Execute an action", ) parser.add_argument( "--loglevel", nargs="?", choices=["debug", "info", "warning", "error", "critical"], help="Loglevel", ) parser.add_argument("--timestamp", action="store_true", help="Show timestamp in output") parser.add_argument("--master-only", action="store_true", help="Only run I2C master") parser.add_argument("--slave-only", action="store_true", help="Only run I2C slave") parser.add_argument( "--slave-timeout", nargs="?", type=int, default=60, help="Slave timeout in seconds when --slave-only", ) parser.add_argument("--no-cache", action="store_true", help="Don't use local cache") parser.add_argument( "--export-to-influxdb", action="store_true", help="Export results to InfluxDB", ) args = parser.parse_args() return args class IthoWPU: def __init__(self, master_only, slave_only, slave_timeout, no_cache): self.master_only = master_only self.slave_only = slave_only self.slave_timeout = slave_timeout self._q = queue.Queue() self.no_cache = no_cache self.cache = IthoWPUCache() self.nodeid = self.get("getnodeid") self.datatype = self.get("getdatatype") self.heatpump_db = db.sqlite("heatpump.sqlite") def get(self, action): if not self.no_cache: response = self.cache.get(action.replace("get", "")) if response is not None: logger.debug(f"Response (from cache): {response}") return response response = None if not self.master_only: slave = I2CSlave(address=0x40, queue=self._q) slave.set_callback() if self.slave_only: time.sleep(self.slave_timeout) if not self.slave_only: master = I2CMaster(address=0x41, bus=1, queue=self._q) if action: response = master.execute_action(action) logger.debug(f"Response: {response}") master.close() if not self.master_only: slave.close() self.cache.set(action.replace("get", ""), response) return response def get_listversion_from_nodeid(self): if self.nodeid is None: return return int(self.nodeid[10], 0) def get_datalog_structure(self): listversion = self.get_listversion_from_nodeid() datalabel_version = self.heatpump_db.execute( f"SELECT datalabel FROM versiebeheer WHERE version = {listversion}" )[0]["datalabel"] if datalabel_version is None or not type(datalabel_version) == int: logger.error(f"Datalabel not found in database for version {listversion}") return None datalabel = self.heatpump_db.execute( f"SELECT name, title, tooltip, unit FROM datalabel_v{datalabel_version} order by id" ) if len(self.datatype[5:-1]) != len(datalabel): logger.warning( f"Number of datatype items ({len(self.datatype[5:-1])}) is not equal to " f"the number of datalabels ({len(datalabel)}) in the database." ) Field = namedtuple("Field", "index type label description") datalog = [] index = 0 for dl, dt in zip(datalabel, self.datatype[5:-1]): dt = int(dt, 0) description = dl["title"].title() if dl["unit"] is not None: description = f"{description} ({dl['unit']})" description = f"{description} ({dl['name'].lower()})" datalog.append(Field(index, dt, dl["name"].lower(), description)) if dt in [0x0, 0x1, 0x2, 0xC, 0xF, 0x6C, 0x80, 0x81, 0x82, 0x8F]: index = index + 1 elif dt in [0x10, 0x11, 0x12, 0x13, 0x14, 0x51, 0x90, 0x91, 0x92]: index = index + 2 elif dt in [0x20, 0x21, 0x22, 0x23, 0x24, 0x25, 0xA0, 0xA1, 0xA2, 0xA3, 0xA4, 0xA5]: index = index + 4 else: logger.error(f"Unknown data type for label {dl['name']}: {dt}") return datalog return datalog class IthoWPUCache: def __init__(self): self._cache_file = "itho-wpu-cache.json" self._cache_data = { "nodeid": None, "serial": None, "datatype": None, "schema_version": "1", } self._read_cache() def _read_cache(self): if not os.path.exists(self._cache_file): logger.debug(f"Not loading cache file: {self._cache_file} does not exist") return with open(self._cache_file) as cache_file: cache_data = json.load(cache_file) logger.debug(f"Loading local cache: {json.dumps(cache_data)}") for key in ["nodeid", "serial", "datatype"]: if key in cache_data: self._cache_data[key] = cache_data[key] def _write_cache(self): with open(self._cache_file, "w") as cache_file: logger.debug(f"Writing to local cache: {json.dumps(self._cache_data)}") json.dump(self._cache_data, cache_file) def get(self, action): if action not in ["nodeid", "serial", "datatype"]: logger.debug(f"Cache for '{action}' is not supported") return None logger.debug(f"Reading '{action}' from local cache") if self._cache_data[action] is None: logger.debug(f"Action '{action}' is not present in local cache") return self._cache_data[action] def set(self, action, value): if action not in ["nodeid", "serial", "datatype"]: logger.debug(f"Cache for '{action}' is not supported") return None logger.debug(f"Writing '{action}' to local cache: {value}") self._cache_data[action] = value self._write_cache() def is_messageclass_valid(action, response): if int(response[1], 0) != actions[action][0] and int(response[2], 0) != actions[action][1]: logger.error( f"Response MessageClass != {actions[action][0]} {actions[action][1]} " f"({action}), but {response[1]} {response[2]}" ) return False return True def process_response(action, response, args, wpu): if int(response[3], 0) != 0x01: logger.error(f"Response MessageType != 0x01 (response), but {response[3]}") return if not is_messageclass_valid(action, response): return if action == "getdatalog": measurements = process_datalog(response, wpu) if args.export_to_influxdb: from itho_export import export_to_influxdb export_to_influxdb(action, measurements) elif action == "getnodeid": process_nodeid(response) elif action == "getserial": process_serial(response) def process_nodeid(response): hardware_info = { 0: { "name": "HCCP", "type": { 13: "WPU", 15: "Autotemp", }, } } manufacturergroup = (int(response[5], 0) << 8) + int(response[6], 0) manufacturer = hardware_info[int(response[7], 0)]["name"] hardwaretype = hardware_info[int(response[7], 0)]["type"][int(response[8], 0)] productversion = int(response[9], 0) listversion = int(response[10], 0) logger.info( f"ManufacturerGroup: {manufacturergroup}, Manufacturer: {manufacturer}, " f"HardwareType: {hardwaretype}, ProductVersion: {productversion}, " f"ListVersion: {listversion}" ) def process_serial(response): serial = (int(response[5], 0) << 16) + (int(response[6], 0) << 8) + int(response[7], 0) logger.info(f"Serial: {serial}") def process_datalog(response, wpu): datalog = wpu.get_datalog_structure() message = response[5:] measurements = {} for d in datalog: if d.type == 0x0 or d.type == 0xC: m = message[d.index : d.index + 1] # noqa: E203 num = int(m[0], 0) elif d.type == 0x10: m = message[d.index : d.index + 2] # noqa: E203 num = (int(m[0], 0) << 8) + int(m[1], 0) elif d.type == 0x12: m = message[d.index : d.index + 2] # noqa: E203 num = round((int(m[0], 0) << 8) + int(m[1], 0) / 100, 2) elif d.type == 0x90: m = message[d.index : d.index + 2] # noqa: E203 num = (int(m[0], 0) << 8) + int(m[1], 0) if num >= 32768: num -= 65536 elif d.type == 0x92: m = message[d.index : d.index + 2] # noqa: E203 num = (int(m[0], 0) << 8) + int(m[1], 0) if num >= 32768: num -= 65536 num = round(num / 100, 2) elif d.type == 0x20: m = message[d.index : d.index + 4] # noqa: E203 num = (int(m[0], 0) << 24) + (int(m[1], 0) << 16) + (int(m[2], 0) << 8) + int(m[3], 0) else: logger.error(f"Unknown message type for datalog {d.name}: {d.type}") logger.info(f"{d.description}: {num}") measurements[d.label] = num return measurements if __name__ == "__main__": args = parse_args() if args.loglevel: logger.setLevel(args.loglevel.upper()) if args.timestamp: stdout_log_handler.setFormatter( logging.Formatter("%(asctime)-15s %(levelname)s: %(message)s") ) wpu = IthoWPU(args.master_only, args.slave_only, args.slave_timeout, args.no_cache) response = wpu.get(args.action) if response is not None: process_response(args.action, response, args, wpu)