feat(itho-wpu): process getdatalog

This commit is contained in:
Pim van den Berg 2020-11-05 14:49:38 +01:00
parent d00e948208
commit c867203913
1 changed files with 63 additions and 1 deletions

View File

@ -7,6 +7,7 @@ import pigpio
import queue
import sys
import time
from collections import namedtuple
consolelogformatter = logging.Formatter("%(asctime)-15s %(levelname)s: %(message)s")
logger = logging.getLogger('stdout')
@ -114,6 +115,64 @@ class I2CMaster:
self.i.close()
def process_response(action, response):
if action == "getdatalog" and int(response[1], 0) == 0xA4 and int(response[2], 0) == 0x01:
measurements = process_datalog(response)
def process_datalog(response):
# 0 = Byte
# 1 = UnsignedInt
# 2 = SignedIntDec2
Field = namedtuple('Field', 'index type label description')
datalog = [
Field(0, 2, "t_out", "Buitentemperatuur"),
Field(2, 2, "t_boiltop", "Boiler laag"),
Field(4, 2, "t_boildwn", "Boiler hoog"),
Field(6, 2, "t_evap", "Verdamper temperatuur"),
Field(8, 2, "t_suct", "Zuiggas temperatuur"),
Field(10, 2, "t_disc", "Persgas temperatuur"),
Field(12, 2, "t_cond", "Vloeistof temperatuur"),
Field(14, 2, "t_source_r", "Naar bron"),
Field(16, 2, "t_source_s", "Van bron"),
Field(18, 2, "t_ch_supp", "CV aanvoer"),
Field(20, 2, "t_ch_ret", "CV retour"),
Field(22, 2, "p_sens", "Druksensor (Bar)"),
Field(24, 2, "i_tr1", "Stroom trafo 1 (A)"),
Field(26, 2, "i_tr2", "Stroom trafo 2 (A)"),
Field(34, 1, "in_flow", "Flow sensor bron (l/h)"),
Field(37, 0, "out_ch", "Snelheid cv pomp (%)"),
Field(38, 0, "out_src", "Snelheid bron pomp (%)"),
Field(39, 0, "out_dhw", "Snelheid boiler pomp (%)"),
Field(44, 0, "out_c1", "Compressor aan/uit"),
Field(45, 0, "out_ele", "Elektrisch element aan/uit"),
Field(46, 0, "out_trickle", "Trickle heating aan/uit"),
Field(47, 0, "out_fault", "Fout aanwezig (0=J, 1=N)"),
Field(48, 0, "out_fc", "Vrijkoelen actief (0=uit, 1=aan)"),
Field(51, 2, "ot_room", "Kamertemperatuur"),
Field(55, 0, "ot_mod", "Warmtevraag (%)"),
Field(56, 0, "state", "State (0=init,1=uit,2=CV,3=boiler,4=vrijkoel,5=ontluchten)"),
Field(57, 0, "sub_state", "Substatus (255=geen)"),
Field(67, 0, "fault_reported", "Fout gevonden (foutcode)"),
Field(92, 1, "tr_fc", "Vrijkoelen interval (sec)"),
]
message = response[5:]
measurements = {}
for d in datalog:
if d.type == 0:
m = message[d.index:d.index+1]
num = int(m[0], 0)
elif d.type == 1:
m = message[d.index:d.index+2]
num = ((int(m[0], 0) << 8) + int(m[1], 0))
elif d.type == 2:
m = message[d.index:d.index+2]
num = round(((int(m[0], 0) << 8) + int(m[1], 0)) / 100.0, 2)
logger.info(f"{d.description}: {num}")
measurements[d.label] = num
return measurements
if __name__ == "__main__":
args = parse_args()
@ -132,8 +191,11 @@ if __name__ == "__main__":
master = I2CMaster(address=0x41, bus=1, queue=q)
if args.action:
result = master.execute_action(args.action)
logger.info(f"Response: {result}")
logger.debug(f"Response: {result}")
master.close()
if result is not None:
process_response(args.action, result)
if not args.master_only:
slave.close()